AFDDs Explained: When Arc Fault Detection Is Required

Arc fault detection devices explained: where BS 7671 requires them on socket circuits, such as HMOs and higher-risk buildings, and where they are advised.

3 min read · 20 November 2026 · RoomPlot Team

Arc fault detection devices, or AFDDs, detect the dangerous arcing that can happen at a loose connection or a damaged cable, before it starts a fire. Since Amendment 2 to BS 7671, they are required in some buildings and recommended in others. Here is where they apply.

BS 7671Where AFDDs are needed PREMISES SOCKET CIRCUITS UP TO 32 A Houses in multiple occupation Required Higher-risk residential buildings Required Other higher-risk premises named in BS 7671 Check the current text Other homes Recommended Single-phase AC final circuits supplying socket-outlets rated up to 32 A. AFDDs sit at the origin of the circuit.
Where AFDDs are required on socket circuits rated up to 32 A, and where they are recommended.

Key takeaways

  • An AFDD detects dangerous arcing from loose connections and damaged cables.
  • BS 7671 requires AFDDs on socket circuits in houses in multiple occupation and higher-risk residential buildings.
  • They are recommended for socket circuits elsewhere.
  • Note AFDD protection in the circuit schedule.

Where they are required

For single-phase AC final circuits supplying socket-outlets rated up to 32 A, AFDDs are required in houses in multiple occupation and higher-risk residential buildings. BS 7671 also names other higher-risk premises, so check the current text for the full list.

For socket circuits in other premises, including ordinary homes, AFDDs are recommended.

How they show up on a plan and a schedule

  • AFDDs sit at the origin of the circuit, in the consumer unit.
  • Mark the protected circuits in the circuit schedule, for example "C3 Sockets ring, RCBO with AFDD".
  • Allow for the extra width of AFDD devices when choosing the consumer unit.

Check the rules. AFDDs do not replace other protective measures in BS 7671. Check the current edition for the full requirements.

Frequently asked questions

Are AFDDs mandatory in UK homes?

Not in ordinary homes, where they are recommended. They are required for socket circuits in some higher-risk residential buildings.

What is the difference between an AFDD and an RCD?

An RCD detects current leaking to earth and protects against shock. An AFDD detects arcing and protects against fire.

Do AFDDs fit in any consumer unit?

In some ranges they are wider than standard devices, so check that the board has room.

Free lesson. Want the full picture? UK rules for electrical plans is part of our free electrical floor plans course, with interactive exercises.

Sources

Plan it on your phone. Name every circuit and its protection on the plan, and the schedule writes itself. Download RoomPlot on the App Store and draw your first electrical plan in minutes, or see what it does on our electricians page.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read