UK rules: BS 7671, Part P and what applies where

Free lesson: the UK rules behind electrical plans: BS 7671:2018+A4:2026, Part P notification, socket heights, RCDs, AFDDs, EICRs and alarms.

10 min · 0 XP · 0 of 18 lessons done

Lesson 10 of 18 All lessons
  1. 1What an electrical floor plan is, and who uses it
  2. 2Electrical symbols: lights, switches, sockets and distribution
  3. 3Circuits explained: lighting, rings, radials and dedicated supplies
  4. 4Drawing the base plan: measuring, doors and fixed fittings
  5. 5Lighting and switching: one-way, two-way and intermediate
  6. 6Sockets and spurs: how many, where, and on which circuit
  7. 7Kitchens and bathrooms: special rules for special rooms
  8. 8Cable routes, lengths and circuit schedules
  9. 9Dedicated circuits: showers, cookers, EV chargers and outbuildings
  10. 10UK rules: BS 7671, Part P and what applies where
  11. 11UK protection: consumer units, RCD types and surge protection
  12. 12UK earthing systems, mounting heights and certificates
  13. 13US rules: the NEC, receptacle spacing, GFCI and AFCI
  14. 14US kitchens and bathrooms: receptacle rules on the plan
  15. 15US panels, GFCI, AFCI and wire sizes
  16. 16Worked example: from survey to a finished plan
  17. 17Checking your plan and handing it over
  18. 18Final test: check what you have learned

In this lesson

  • BS 7671:2018+A4:2026 is the current wiring standard.
  • New circuits, consumer units and bathroom work are usually notifiable in England.
  • Rented homes need an EICR at least every five years.

In the UK, electrical plans describe installations that must follow BS 7671 and, in England, the Building Regulations. This lesson is your map of the rules that matter for domestic work.

BS 7671The road to Amendment 4 2022 Amendment 2 AFDD and socket RCD changes 15 Jan 2026 A4 announced IET and BSI publish details 15 Apr 2026 A4 published Can be used straight away 15 Oct 2026 Transition ends Earlier version withdrawn
BS 7671 Amendment 4 was published on 15 April 2026 and the earlier version withdrawn on 15 October 2026.

BS 7671, the IET Wiring Regulations

BS 7671:2018+A4:2026 is the current edition. Amendment 4 adds a chapter on stationary batteries, a section on Power over Ethernet and major changes to medical locations. Key domestic points include 30 mA RCD protection for most socket circuits up to 32 A, AFDDs in HMOs and higher-risk residential buildings, and Section 701 for bathrooms.

Part P (England)

ENGLAND, PART PNotifiable or not? USUALLY NOTIFIABLE Installing a new circuit Replacing a consumer unit New work in a room with a bath or shower USUALLY NOT NOTIFIABLE Replacing a socket, switch or fitting like for like Repairing a damaged cable Adding a point to an existing circuit, outside special locations
Part P: what is usually notifiable, and what usually is not.

New circuits, consumer unit replacements and new work in rooms with a bath or shower are usually notifiable, through a registered competent person, a third-party certifier or building control.

Accessibility

For new dwellings in England, Approved Document M points switches and sockets to between 450 mm and 1200 mm above the finished floor.

Rented homes

Private landlords, and now social landlords, must have the installation inspected at least every five years and act on C1, C2 and FI findings within 28 days.

Alarms

Domestic fire alarms follow BS 5839-6, with grades and categories that decide where alarms go; landlords in England also have smoke and carbon monoxide alarm duties.

Wales, Scotland and Northern Ireland have their own building standards. BS 7671 applies across the UK.

Try it

Write down three jobs: a new kitchen circuit, a replacement light switch and a new shower. Which are notifiable in England?

Check your understanding

Official documents and further reading

Progress is saved in this browser.

Go deeper: related guides

Electricians BS 7671 Amendment 4 (2026) Explained in Simple Words BS 7671:2018+A4:2026 explained simply: when it was published, when the old version was withdrawn, and what changed for batteries, PoE and inspections. 3 min read Electricians Part P Explained: What Electrical Work Is Notifiable in England? Part P of the Building Regulations explained: which electrical work in homes is notifiable, such as new circuits and consumer units, and who can self-certify. 3 min read Electricians AFDDs Explained: When Arc Fault Detection Is Required Arc fault detection devices explained: where BS 7671 requires them on socket circuits, such as HMOs and higher-risk buildings, and where they are advised. 3 min read