Module 2 · Designing a layout · Lesson 8 of 18

Cable routes, lengths and circuit schedules

Free lesson: draw realistic cable routes, estimate cable length from the plan, and write a circuit schedule that matches the board.

7 min · 0 XP · 0 of 18 lessons done

Lesson 8 of 18 All lessons
  1. 1What an electrical floor plan is, and who uses it
  2. 2Electrical symbols: lights, switches, sockets and distribution
  3. 3Circuits explained: lighting, rings, radials and dedicated supplies
  4. 4Drawing the base plan: measuring, doors and fixed fittings
  5. 5Lighting and switching: one-way, two-way and intermediate
  6. 6Sockets and spurs: how many, where, and on which circuit
  7. 7Kitchens and bathrooms: special rules for special rooms
  8. 8Cable routes, lengths and circuit schedules
  9. 9Dedicated circuits: showers, cookers, EV chargers and outbuildings
  10. 10UK rules: BS 7671, Part P and what applies where
  11. 11UK protection: consumer units, RCD types and surge protection
  12. 12UK earthing systems, mounting heights and certificates
  13. 13US rules: the NEC, receptacle spacing, GFCI and AFCI
  14. 14US kitchens and bathrooms: receptacle rules on the plan
  15. 15US panels, GFCI, AFCI and wire sizes
  16. 16Worked example: from survey to a finished plan
  17. 17Checking your plan and handing it over
  18. 18Final test: check what you have learned

In this lesson

  • Route cables the way they will really run.
  • Length on plan plus vertical drops plus a margin gives a realistic estimate.
  • Use the same circuit names on the plan, the schedule and the board.

Cable routes turn a plan of points into a plan you can build. This lesson covers drawing them, measuring them and writing the schedule.

USB 2.7 m 6.3 m 3.0 m 6.6 m 5.3 m Cable lengths Kitchen ring and cooker runs CIRCUITS (CABLE ROUTES) C2 Kitchen ring 2.5 mm² · 32 A RCBO 19.0 m on plan C4 Cooker 6 mm² · 32 A RCBO · 7.7 m on plan SYMBOLS Double socket Fused spur Cooker Control Unit Consumer Unit
Each run of the kitchen ring and the cooker circuit labelled with its length.

Draw realistic routes

Route cables along joists and walls, with right-angle bends, rather than straight across rooms. Keep data cables apart from mains cables. Give each circuit its own colour.

Estimate the length

  1. Take the length on plan from each route.
  2. Add a vertical drop for each accessory, up or down the wall.
  3. Add an allowance for terminations and a margin, often around 10 percent.

Length also matters for voltage drop, which may require a larger cable on long runs.

Write the schedule

For each circuit, record its number and name, the protective device, the cable size and what it serves. BS 7671 expects a durable chart or schedule at the distribution board, and the same names should appear on the plan.

Free calculators for this lesson: voltage drop calculator, UK cable size calculator.

Try it

For one circuit in your plan, add up the length on plan, the drops and a 10 percent margin.

Check your understanding

Official documents and further reading

Go deeper: related guides

Electricians How to Estimate Cable Length from a Floor Plan Estimate cable length from a floor plan: measured run lengths per circuit, vertical drops, termination allowance and a margin, totalled for the quote. 3 min read Electricians Consumer Unit Circuit Schedule: Match the Board to the Plan Write a consumer unit circuit schedule that matches the electrical floor plan: one row per way, ratings, cable sizes and what each circuit feeds. 3 min read Electricians How to Quote an Electrical Job from a Floor Plan Quote electrical work accurately from a floor plan: count points per room, list circuits and extras, and send the plan with the quote so clients can check it. 3 min read