Consumer Unit Circuit Schedule: Match the Board to the Plan

Write a consumer unit circuit schedule that matches the electrical floor plan: one row per way, ratings, cable sizes and what each circuit feeds.

3 min read · 20 November 2026 · RoomPlot Team

Every distribution board needs a schedule that tells the next person what each way does. The best schedules are written straight from the electrical floor plan, so the labels on the board, the chart on the door and the drawing all use the same names. This guide shows how to build one.

What the schedule needs to show

BS 7671 expects a durable diagram, chart or schedule at or near each distribution board. In practice, a good one gives every way:

  • The circuit number and a plain description of what it feeds.
  • The type and rating of the protective device, for example a B32 RCBO.
  • The cable size and type.
  • The points served, so a fault can be traced quickly.
Consumer unit One RCBO per circuit, each way labelled to match the plan Main switch 100 A DP SPD Type 2 C1 B6 RCBO 30 mA 1.5 mm² Lighting C2 B32 RCBO 30 mA 2.5 mm² Kitchen ring C3 B32 RCBO 30 mA 2.5 mm² Sockets ring C4 B32 RCBO 30 mA 6 mm² Cooker C5 B20 RCBO 30 mA 2.5 mm² Garage radial C6 B32 RCBO 30 mA 6 mm² EV charger Ratings shown are typical for this sample house. Confirm each one against the design, cable length and installation method.
A consumer unit with one RCBO per circuit. The colour on each way matches the circuit colour on the electrical floor plan.

Key takeaways

  • Every distribution board needs a durable schedule that says what each way feeds.
  • Name circuits on the plan exactly as they appear on the board.
  • One RCBO per circuit keeps a fault local and the schedule simple.
  • When a circuit changes, update the plan first and then the schedule.

A sample schedule

This is the schedule for the sample house used across our electrician guides:

WayCircuitDeviceCableServes
C1LightingB6 RCBO1.5 mm²All lights, alarm supply
C2Kitchen ringB32 RCBO2.5 mm²Worktop sockets, appliance spurs
C3Sockets ringB32 RCBO2.5 mm²Bedroom and hall sockets
C4CookerB32 RCBO6 mm²Cooker control unit
C5Garage radialB20 RCBO2.5 mm²Garage sockets
C6EV chargerB32 RCBO6 mm²Charge point (DC fault protection)

Ratings like these are typical for a small house, not a design. Size each one from the load, the cable length, the installation method and voltage drop.

Why one RCBO per circuit

With 30 mA RCD protection now expected on most domestic circuits, many installers fit an RCBO to every way. A fault then trips only its own circuit instead of half the house, and the schedule stays simple: one way, one circuit, one colour on the plan.

Tip. Name each circuit on the plan exactly as it will appear on the board, for example "C2 Kitchen ring". RoomPlot carries circuit names and colours into the exported legend and cable schedule, so the drawing and the door chart never disagree.

Common mistakes

  • "Sockets 1" and "Sockets 2". Say which rooms each circuit feeds, so a fault can be traced without testing everything.
  • A schedule that disagrees with the plan. Use the same circuit names in both, from the start.
  • Missing spare ways. Leave room on the board, and on the schedule, for the circuits that will come later.
  • Handwritten labels that fade. The schedule should be durable and stay legible for the life of the installation.

Keep it current

When a circuit is added or altered, update the plan first, then the schedule. Because the plan lives in one project, the next export already carries the change. Read more guides for the trade on our electricians page, or see how to build a full PDF report.

Frequently asked questions

What should a circuit schedule include?

The circuit number and description, the type and rating of the protective device, the cable size and the points served.

Is a circuit chart a requirement?

BS 7671 expects a diagram, chart or schedule at or near each distribution board so that circuits can be identified.

What does B32 mean on a breaker?

B is the trip curve, which suits ordinary domestic loads, and 32 is the rated current in amps.

Free lesson. Want the full picture? Circuits explained is part of our free electrical floor plans course, with interactive exercises.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read