Lesson 3 of 18 All lessons
- 1What an electrical floor plan is, and who uses it
- 2Electrical symbols: lights, switches, sockets and distribution
- 3Circuits explained: lighting, rings, radials and dedicated supplies
- 4Drawing the base plan: measuring, doors and fixed fittings
- 5Lighting and switching: one-way, two-way and intermediate
- 6Sockets and spurs: how many, where, and on which circuit
- 7Kitchens and bathrooms: special rules for special rooms
- 8Cable routes, lengths and circuit schedules
- 9Dedicated circuits: showers, cookers, EV chargers and outbuildings
- 10UK rules: BS 7671, Part P and what applies where
- 11UK protection: consumer units, RCD types and surge protection
- 12UK earthing systems, mounting heights and certificates
- 13US rules: the NEC, receptacle spacing, GFCI and AFCI
- 14US kitchens and bathrooms: receptacle rules on the plan
- 15US panels, GFCI, AFCI and wire sizes
- 16Worked example: from survey to a finished plan
- 17Checking your plan and handing it over
- 18Final test: check what you have learned
In this lesson
- Lighting usually runs as radials; UK sockets often as ring finals.
- Big loads such as cookers, showers, heat pumps and EV chargers get dedicated circuits.
- Every circuit starts at a protective device in the consumer unit or panel.
Before you place a single symbol, it helps to know how a home's electrics are organised. Every point belongs to a circuit, and every circuit starts at a protective device.
The main circuit types
- Lighting radials: one cable runs out from the board to each light in turn, commonly on a 6 A device in the UK.
- Ring finals (UK): a loop of 2.5 mm² cable that leaves the board, visits every socket and returns, on a 32 A device, typically serving up to about 100 m².
- Radials for sockets: a single run, such as 2.5 mm² on 20 A for a smaller area. US homes use radial branch circuits throughout, commonly on 15 A or 20 A breakers.
- Dedicated circuits: one circuit for one large load, such as a cooker, shower, heat pump or EV charger.
Protective devices
Circuit breakers protect against overload and short circuit. RCDs protect people by detecting current leaking to earth, and UK socket circuits up to 32 A generally need 30 mA RCD protection. An RCBO combines both in one device, so a fault only trips its own circuit. In the US, GFCI and AFCI protection play similar roles for specific locations.
Conductor colours
UK: brown line, blue neutral, green-and-yellow protective conductor. US: black or red hot, white neutral, green or bare ground. On the plan, colours identify circuits, not conductors.
Try it
Look at the labels in your own consumer unit or panel and write down every circuit. Which ones are lighting, which are sockets and which are dedicated?