Lesson 2 of 18 All lessons
- 1What an electrical floor plan is, and who uses it
- 2Electrical symbols: lights, switches, sockets and distribution
- 3Circuits explained: lighting, rings, radials and dedicated supplies
- 4Drawing the base plan: measuring, doors and fixed fittings
- 5Lighting and switching: one-way, two-way and intermediate
- 6Sockets and spurs: how many, where, and on which circuit
- 7Kitchens and bathrooms: special rules for special rooms
- 8Cable routes, lengths and circuit schedules
- 9Dedicated circuits: showers, cookers, EV chargers and outbuildings
- 10UK rules: BS 7671, Part P and what applies where
- 11UK protection: consumer units, RCD types and surge protection
- 12UK earthing systems, mounting heights and certificates
- 13US rules: the NEC, receptacle spacing, GFCI and AFCI
- 14US kitchens and bathrooms: receptacle rules on the plan
- 15US panels, GFCI, AFCI and wire sizes
- 16Worked example: from survey to a finished plan
- 17Checking your plan and handing it over
- 18Final test: check what you have learned
In this lesson
- Use one symbol family for each kind of device on a sheet.
- Switches: one-way, two-way and intermediate (three-way and four-way in the US).
- Always include a legend generated from the symbols used.
Symbols are the vocabulary of an electrical plan. In this lesson you will learn the core set used on almost every home, with the UK and US name for each.
Lighting
Lights are usually the most numerous points. Pendants, surface ceiling lights, recessed downlights, wall lights and outdoor lights each have their own symbol, so the plan doubles as a fitting count.
Switches
- One-way: one switch controls one or more lights.
- Two-way: two switches control the same light, for example at the top and bottom of a stair.
- Intermediate: added between two two-way switches for a third control point.
- Dimmer, double pole and pull-cord switches complete the set.
Sockets and spurs
Sockets (receptacles in the US) are drawn touching the wall they are mounted on. Single and double sockets, USB, weatherproof and GFCI versions all have variants. A fused spur feeds fixed equipment such as a boiler or an integrated appliance.
Distribution and safety
The consumer unit (UK) or panelboard (US) marks where circuits start. Smoke, heat and carbon monoxide alarms, extractor fans, the cooker control and EV chargers each have their own symbol.
Standards
UK drawings traditionally follow IEC 60617 style graphical symbols (BS EN 60617). In RoomPlot the same light, switch and socket symbols are used on UK and US plans, and the UK or US filter only changes the names, for example two-way and three-way, or double socket and duplex receptacle. What matters most on a real job is consistency and a clear legend.
Try it
Draw five symbols from memory: a pendant light, a one-way switch, a two-way switch, a double socket and a consumer unit. Then compare with the chart above.