How to Estimate Cable Length from a Floor Plan

Estimate cable length from a floor plan: measured run lengths per circuit, vertical drops, termination allowance and a margin, totalled for the quote.

3 min read · 20 November 2026 · RoomPlot Team

Under-order cable and the job stops; over-order and the margin disappears into offcuts. Measuring each run on a scaled floor plan gives a far better estimate than pacing the house, and it doubles as the figure you need for voltage drop. This guide shows a simple, repeatable method.

Step 1 - Draw every run as a cable route

On a measured plan, draw each circuit as a cable route following the way the cable will really run: along joists, up walls and around obstacles, not straight across the room. Right-angle routing is usually closer to reality than a straight line. In RoomPlot each route reports its length on plan, and Connections between switches and lights are excluded from the totals because they are relationships, not cable.

USB 2.7 m 6.3 m 3.0 m 6.6 m 5.3 m Cable lengths Kitchen ring and cooker runs CIRCUITS (CABLE ROUTES) C2 Kitchen ring 2.5 mm² · 32 A RCBO 19.0 m on plan C4 Cooker 6 mm² · 32 A RCBO · 7.7 m on plan SYMBOLS Double socket Fused spur Cooker Control Unit Consumer Unit
Each straight run of the kitchen ring (blue) and the cooker circuit (purple) labelled with its length, with the circuit totals in the legend.

Key takeaways

  • Draw each run the way the cable will really go, not straight across the room.
  • Add the vertical drops to every switch, socket and spur.
  • Add a margin, often about 10%, for terminations and waste.
  • The measured length also feeds the voltage drop check.

Step 2 - Add the vertical drops

A plan is two dimensional, but cable also runs up and down walls to every socket, switch and spur. RoomPlot shows a route as an estimate until you set its height allowance. A practical method is to count the accessories on the circuit and add a drop for each one, based on ceiling height and mounting height.

Step 3 - Allow for terminations and waste

Add a little at every termination and a margin for the unexpected. Many electricians add around 10 percent on top of the measured total, more on awkward refurbishments.

CircuitLength on planDropsSubtotalWith 10% margin
C2 Kitchen ring19.0 m8.0 m27.0 m30 m
C4 Cooker7.7 m1.2 m8.9 m10 m

Tip. Set the cable label to show length and the circuit name. The plan then shows where the metres go, and the report totals them per circuit for the order.

Common mistakes

  • Straight-line runs. Cables follow joists and walls, so route them that way on the plan.
  • Forgetting the drops. Every socket, switch and spur adds cable running up or down a wall.
  • Counting switch connections as cable. Only physical cable routes belong in the order.
  • Ordering to the metre. Keep a margin for terminations and the joist you did not expect.

Length also drives cable size

Long runs increase voltage drop. BS 7671 gives limits for voltage drop between the origin and the equipment, so a long run to a garage, an outbuilding or an EV charger can need a larger cable than the current alone suggests. Measuring the route on the plan gives you the length you need for that check. More trade guides are on our electricians page.

Frequently asked questions

How do I calculate how much cable I need?

Measure each circuit route on a scaled plan, add the drops up and down walls, then add a margin of around 10%.

Do switch connections count as cable?

No. In RoomPlot a connection shows which switch controls which light. Only cable routes are measured.

Why does cable length matter for cable size?

Longer runs lose more voltage, so a long run can need a larger cable than the current alone would suggest.

Free lesson. Want the full picture? Cable routes and schedules is part of our free electrical floor plans course, with interactive exercises.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read