A bedroom is where small electrical decisions matter every day: getting out of bed to switch off the light, stretching a charger cable across the floor, or a TV with no data point. A ten-minute plan fixes all of it. This guide shows what to put where.

Bed Wardrobe 6 Bedroom Bedroom plan Two-way light from the door and the bed C1 Lighting Pendant and reading lights C3 Sockets Either side of the bed Connection (switch to light) SYMBOLS Pendant fixture light Wall light Double socket 6 Cat6 network outlet Two-way switch One-way switch
A bedroom plan with sockets and reading lights either side of the bed, a pendant switched two-way from the door and the bedside, and power and data by the wardrobe.

Key takeaways

  • Place the bed first: everything else follows from it.
  • Fit double sockets on both sides of the bed, ideally with USB.
  • Use two-way switching so the main light works from the door and from the bed.
  • Check the door swing before fixing the switch position.

What to plan

  • Sockets either side of the bed, at bedside table height, ideally double sockets with USB.
  • Reading lights on each side, each with its own switch.
  • Two-way switching for the main light: one switch by the door, one by the bed.
  • Power and data for a TV or a desk, if the room will have one.
  • A spare socket near the door for a vacuum cleaner or a heater.

Step by step

  1. Draw the room and place the bed first. Everything else follows from the bed.
  2. Put sockets and reading lights on both sides of the headboard.
  3. Place the main light, then a two-way switch by the door on the latch side and another by the bed.
  4. Add power and data where the TV or desk will go.
  5. Link each switch to its light and draw the lighting and socket routes.

Tip. Check the door swing on the plan before you fix the switch position. A switch behind the open door is a daily annoyance.

Smoke alarms in bedrooms

Depending on the property and its use, the fire alarm specification may call for a smoke alarm in bedrooms as well as on the escape route. Check the category the job needs, and if alarms are included, put them on the plan with their interlink.

Frequently asked questions

How many sockets should a bedroom have?

Four to six doubles in a main bedroom is a good target: both sides of the bed, a dressing table or desk, the TV position and a spare.

What is two-way switching in a bedroom?

Two switches controlling the same light, one by the door and one by the bed.

Do bedrooms need smoke alarms?

It depends on the fire alarm category specified for the property. Some specifications include bedrooms as well as the escape route.

Free lesson. Want the full picture? Lighting and switching is part of our free electrical floor plans course, with interactive exercises.

Plan it on your phone. Place the bed, add sockets and lights either side and link the switches, all on one screen. Download RoomPlot on the App Store and draw your first electrical plan in minutes, or see what it does on our electricians page.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read
Browse all guides