Electricians

GFCI Requirements by Room: Where the NEC Requires Ground-Fault Protection

Where GFCI protection is required in a US home, room by room: kitchens, bathrooms, garages, outdoors, basements and laundry areas, shown on a floor plan.

3 min read · 21 November 2026 · RoomPlot Team

A ground-fault circuit interrupter cuts the power in a fraction of a second when current leaks where it should not, for example through a person standing on a wet floor. The National Electrical Code lists the places in a home where receptacles must have it. A floor plan is the quickest way to see them all.

GFCI GFCI GFCI OUTDOORS: GFCI OUTDOORS: GFCIKitchen Bathroom Bedroom Garage Where GFCI is required NEC 210.8(A), dwelling units GFCI protection Kitchen, bathroom, garage, outdoors Also in the list Basements, laundry areas, crawl spaces, and within 6 ft of a sink, tub or shower
A house plan with the GFCI areas shaded: kitchen, bathroom, garage and outdoor receptacles.

Key takeaways

  • GFCI protection is about location: anywhere water, damp or bare earth makes a shock more dangerous.
  • Kitchens, bathrooms, garages, outdoors, basements, crawl spaces and laundry areas are all on the list.
  • Receptacles within 6 ft of a sink, bathtub or shower stall need it wherever they are.
  • Protection can come from a GFCI receptacle or a GFCI breaker.

The list for dwellings

NEC 210.8(A) requires GFCI protection for receptacles in these locations:

  • Bathrooms.
  • Garages and accessory buildings with a floor at or below grade.
  • Outdoors.
  • Crawl spaces at or below grade.
  • Basements.
  • Kitchens. The 2023 edition covers all kitchen receptacles, not only those serving the countertop.
  • Sinks: receptacles within 6 ft of the bowl's edge.
  • Bathtubs and shower stalls: receptacles within 6 ft.
  • Laundry areas.
  • Boathouses and indoor damp or wet locations.

Recent editions apply the rule to 125 V through 250 V receptacles, which brings in many dryer and range receptacles in these locations too.

Check the rules. States and cities adopt different editions of the NEC, often with local amendments. This guide is a plain-English summary based on recent editions. Always check the edition your jurisdiction enforces and ask your inspector when in doubt.

Receptacle or breaker?

A GFCI receptacle protects itself and, if wired that way, the receptacles downstream of it on the same circuit. It is cheap and the reset button is where the user is. A GFCI breaker protects the whole circuit from the panel, which suits circuits with many receptacles or receptacles in awkward places. Either way, the device must be readily accessible, so not behind a refrigerator.

Marking GFCI on a plan

On a drawing, a GFCI receptacle is the duplex receptacle symbol with the letters GFCI beside it. RoomPlot has this symbol in its electrical library, along with a weatherproof version for outdoor locations. Marking them on the plan before rough-in makes the inspection conversation short.

Tip. Press the test button on each GFCI once a month. If the reset button does not pop out and cut the power, replace the device.

A room-by-room walk-through

Room or areaGFCI for receptacles?
KitchenYes
BathroomYes
GarageYes
Outdoors, decks and porchesYes
BasementYes
Laundry areaYes
Bedroom or living roomOnly within 6 ft of a sink, such as a wet bar

Frequently asked questions

Do all kitchen outlets need GFCI?

Under the 2023 NEC, yes. Earlier editions required it for receptacles serving countertops and those within 6 ft of the sink.

Does a refrigerator need GFCI protection?

If it is plugged into a receptacle in a location on the list, such as a kitchen under the 2023 edition or a garage, that receptacle needs GFCI protection.

What is the difference between GFCI and AFCI?

A GFCI protects people from shock by detecting current leaking to ground. An AFCI protects against fire by detecting dangerous arcing in the wiring.

Free lesson. Want the full picture? US rules for electrical plans is part of our free electrical floor plans course, with interactive exercises.

Sources

Plan it on your phone. Mark every GFCI location on the plan before rough-in and export it for the inspector. Download RoomPlot on the App Store and draw your first electrical plan in minutes, or see what it does on our electricians page.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read
Browse all guides