Heat pumps are being installed in record numbers in the UK, helped by the Boiler Upgrade Scheme. Every one needs an electrical supply that is planned properly: a dedicated circuit, local isolation and controls cabling to the cylinder and the wiring centre. This guide shows what to put on the plan.
Key takeaways
- A heat pump needs a dedicated circuit sized to the manufacturer's rating.
- Fit a local isolator beside the outdoor unit.
- Check maximum demand, especially alongside an EV charger or electric cooking.
- Draw controls cabling as a separate route.
The supply
- A dedicated circuit from the consumer unit, sized to the manufacturer's rating.
- A local isolator beside the outdoor unit, usually a weatherproof rotary isolator.
- RCD protection where required, of a type the manufacturer specifies.
- Supply capacity: check maximum demand, especially if an EV charger or electric cooking is also planned.
Controls and hot water
Heat pumps come with controls cabling to a wiring centre, room thermostats and the hot water cylinder, which often has an immersion heater as backup. Draw these as a separate, dashed route so they are not mistaken for mains circuits.
Where the outdoor unit goes
The outdoor unit needs airflow, a solid base and a position that respects noise limits and any permitted development rules. Put it on the plan early: its position decides the cable route, the isolator position and often the consumer unit capacity check.
Check the rules. Heat pump installations funded by the Boiler Upgrade Scheme are installed by certified installers. The electrical work must follow the current edition of BS 7671 and the manufacturer's instructions.
For grant values and eligibility, see the current GOV.UK guidance on the Boiler Upgrade Scheme.
Frequently asked questions
Does a heat pump need its own circuit?
Yes. It has a dedicated circuit from the consumer unit, with a local isolator at the outdoor unit.
Will I need a bigger electricity supply?
Not always. An electrician checks the maximum demand of the home, and the network operator is told about the installation.
What RCD does a heat pump need?
The type the manufacturer specifies. Inverter-driven units often call for Type A, F or B instead of Type AC.