Home batteries are now common alongside solar panels, and where they go matters for fire safety. PAS 63100:2024 from BSI sets out how battery energy storage systems should be protected against fire in homes, including which locations to avoid. Here it is in plain English, drawn on a floor plan.
Key takeaways
- PAS 63100 covers fire safety for battery storage in homes.
- Batteries should not go in rooms where people sleep or on escape routes.
- An outside wall, away from doors and windows, is often the simplest location.
- Mark the battery and the excluded areas on the plan early.
Where not to put a battery
- Rooms where people sleep, and cupboards that open into them.
- Escape routes, such as the hall and stairs.
- Summaries also list lofts and roof spaces, and basements without direct outside access, as unsuitable.
Where a battery can often go
- Outside, on a wall, with summaries citing at least 1 m from doors, windows, ventilation openings and escape routes.
- Indoors in suitable locations with fire-resisting separation from the rest of the home and fire detection, as the PAS requires.
- Garages need care: check separation, detection and the manufacturer's instructions.
Show it on the plan
The battery position affects the cable route to the inverter, the location of isolators and the fire detection design. Mark the battery and the excluded areas on the floor plan early, so the customer understands why it cannot go in the cupboard they first suggested.
Check the rules. PAS 63100 is guidance rather than law, and the summaries above come from industry sources. Amendment 4 to BS 7671 also adds requirements for stationary batteries. Check the published texts and the manufacturer's instructions for each installation.
Frequently asked questions
Can a home battery go in the loft?
Industry summaries of PAS 63100 list lofts and roof spaces as unsuitable locations.
Can a battery go in a garage?
Often, with care. Check separation from the house, fire detection and the manufacturer's instructions.
Is PAS 63100 a legal requirement?
It is guidance, not law, but it is widely used as the benchmark for a safe installation.