A lighting layout answers two questions: where are the lights, and which switch turns each one on. Get both onto the plan and first fix becomes a straightforward job. This guide covers how a domestic lighting circuit is usually arranged in the UK, how to show switching clearly, and how two-way and intermediate switching look when drawn properly.

How a domestic lighting circuit is laid out

Most UK homes run lighting as radial circuits, commonly in 1.0 or 1.5 mm² twin and earth on a 6 A protective device, often one circuit per floor so a fault never leaves a whole house dark. Power reaches each light either by looping in at the ceiling rose or through junction boxes, with a switch drop down the wall to each switch. Bathrooms, outdoor lights and fans are usually fed from the same circuit through the right accessories.

C1 Kitchen Bathroom Bedroom Garage Lighting circuit Cable route plus switch connections CIRCUITS (CABLE ROUTES) C1 Lighting 1.5 mm² · 6 A RCBO Connection (switch to light) SYMBOLS Pendant fixture light Surface ceiling light Recessed ceiling light One-way switch Two-way switch Dimmer switch Consumer Unit
A lighting circuit on one cable route (yellow) with red Connections showing which switch controls which light, including a hall light switched from both ends.

Key takeaways

  • Most UK homes wire lighting as radial circuits on a 6 A device, often one circuit per floor.
  • Show control with a connection from each switch to its lights, and keep cable routes separate.
  • Two two-way switches control a light from two places. An intermediate switch adds a third.
  • Check the door swing before fixing a switch position.

Show switching with Connections, not guesses

In RoomPlot, the yellow cable route is the physical run and its length counts towards cable quantities. The red Connections are relationships: this switch controls these lights. Keeping the two apart is what makes the plan readable. In the example above you can see at once that the kitchen switch controls two lights, the bathroom switch three downlights and the bedroom dimmer two pendants.

  • Put switches on the latch side of doors so they fall to hand as the door opens.
  • For new dwellings in England, Approved Document M points switches and sockets to between 450 mm and 1200 mm above finished floor level.
  • Bathroom lights are usually switched from outside the room or by a pull cord inside.

Two-way and intermediate switching

A light controlled from two places uses two two-way switches joined by two strappers. Add an intermediate switch between them and you gain a third control point, which is common on landings and long hallways. The strappers usually run in three-core and earth cable. Because the grey and black cores carry line voltage, they are sleeved brown at every termination, and the bare protective conductor is sleeved green-and-yellow.

Switch A (two-way)Bottom of the stairs COM L1 L2 IntermediateLanding L1 L2 L1 L2 Switch B (two-way)Top of the stairs COM L1 L2 Line in from the lighting circuit Switched line NeutralLanding light Brown sleeve: strappers carry line voltageGrey strapperBlack strapper
Two two-way switches and an intermediate switch joined by grey and black strappers, each sleeved brown at the terminals, controlling one landing light.

Tip. Draw one Connection from each switch to the same light for two-way switching. Anyone reading the plan sees two control points without needing a separate wiring diagram.

Common mistakes

  • Drawing switch legs as cable. A Connection shows control; only cable routes should count towards quantities.
  • Unsleeved strappers. Grey and black cores used as line conductors need brown sleeving at both ends.
  • Switches behind the door. Check the door swing on the plan before you fix a switch position.
  • One circuit for the whole house. Splitting lighting by floor keeps a single fault from leaving everyone in the dark.

From plan to quantities

Label each lighting route with its length on plan and add a height allowance for the drops to switches, and the report gives you a realistic cable figure for the circuit. Export it as a branded PDF report with the legend, or share an image with the client before first fix. More guides for the trade are on our electricians page.

Frequently asked questions

How many lights can go on one lighting circuit?

There is no fixed count. The limit is the load on the circuit and its protective device. With LED fittings a 6 A circuit comfortably serves a floor, and splitting by floor limits the effect of a fault.

What cable is used for a lighting circuit in the UK?

Commonly 1.0 or 1.5 mm² twin and earth, with three-core and earth between two-way switches. The designer confirms the size for the route and its length.

How do I show two-way switching on a plan?

Place a two-way switch at each position and draw a connection from each one to the same light.

Free lesson. Want the full picture? Lighting and switching is part of our free electrical floor plans course, with interactive exercises.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read