"What height should sockets be?" is one of the most searched questions in UK electrics, and the answer is often given wrongly. The heights come from building regulations about accessibility, not from the wiring regulations, and they apply to new homes. Here is what the documents say.
Key takeaways
- In new homes in England, sockets and switches in habitable rooms are fitted between 450 mm and 1200 mm from the floor.
- Consumer units in new homes are mounted with their switches between 1350 mm and 1450 mm from the floor.
- These figures come from Approved Document M, not BS 7671.
- They are not mandatory for a rewire of an existing home, but they are good practice.
Where the 450 to 1200 mm rule comes from
Approved Document M of the Building Regulations for England covers access to and use of buildings. For new dwellings it says that switches, sockets and other controls in habitable rooms should have their centre line between 450 mm and 1200 mm above the floor, so that people who cannot bend or reach easily can use them.
The consumer unit
The same document says consumer units in new dwellings should be mounted so that the switches are between 1350 mm and 1450 mm above floor level: high enough to be out of reach of small children and low enough to be reached without a step.
What BS 7671 says
The wiring regulations do not give a number. They require equipment to be accessible for operation and maintenance and to be suitable for its location. So a socket at skirting height in an old house does not break BS 7671 simply because of its height.
Kitchens
Above a worktop, sockets are commonly fitted with about 150 mm between the worktop and the bottom of the plate, which keeps plugs and cables clear of the surface. Guidance also recommends keeping sockets away from sinks and not fitting them directly above hobs. These are good-practice figures from industry guidance, not fixed legal distances.
Check the rules. Scotland, Wales and Northern Ireland have their own building standards with similar but not identical requirements. Check the document for your nation and the current edition.
Rewires and extensions
When an existing home is rewired, the building regulations do not force the new accessories to the accessible heights. Many electricians and clients choose them anyway. An extension is new building work, so the heights apply to the new rooms.
Put the heights on the plan
A plan shows position along the wall but not height, so write the mounting heights in a note: "sockets 450 mm, switches 1200 mm, worktop sockets 150 mm above worktop". On a RoomPlot plan, a short text label next to the legend does the job, and everyone on site works to the same figures.
Frequently asked questions
What is the standard height for a light switch in the UK?
In new homes in England, between 450 mm and 1200 mm to the centre. Many installers fit switches at around 1200 mm, or lower to align with door handles.
What is the minimum height for a socket?
In new homes in England, 450 mm from the floor to the centre of the socket.
Do I have to move sockets in an older house?
No. The heights apply to new dwellings and new building work. Existing sockets can stay where they are.
Free lesson. Want the full picture? Sockets and spurs is part of our free electrical floor plans course, with interactive exercises.
Sources
- GOV.UK: Approved Document M, access to and use of buildings
- IET: BS 7671, the Wiring Regulations
- Electrical Safety First: Best Practice Guides
Plan it on your phone. Place every socket and switch on the plan and add the mounting heights as a note for the whole team. Download RoomPlot on the App Store and draw your first electrical plan in minutes, or see what it does on our electricians page.