Electrical
Receptacle Spacing Calculator
Enter the length of an unbroken wall or countertop run. You get the minimum number of receptacles and an even layout that meets the rule.
Fill in the fields above to see results.
How it works
For general wall space, NEC 210.52(A) says no point along the floor line may be more than 6 ft from a receptacle, so receptacles are at most 12 ft apart and within 6 ft of each end. For kitchen countertops, 210.52(C) tightens this to 24 in, so receptacles are at most 4 ft apart and within 2 ft of each end. Measure each unbroken run separately: doorways break a wall, and a sink or range breaks a countertop. Local amendments can differ.
Frequently asked questions
How many outlets does a 14 ft wall need?
Two. One receptacle can cover 12 ft of wall, so 14 ft needs two, each within 6 ft of an end.
Does a 2 ft wall need a receptacle?
Yes. Any wall space 2 ft or more wide counts and needs to be within 6 ft of a receptacle.