Electricians

Kitchen Electrical Plan: Sockets, Spurs and the Cooker Circuit

Plan kitchen electrics on a floor plan: worktop sockets, fused spurs for appliances, a dedicated cooker circuit with a control unit, and kitchen lighting.

3 min read · 20 November 2026 · RoomPlot Team

The kitchen carries more electrical load than any other room, and it is where poor planning shows first: sockets behind the fridge, a cooker switch nobody can reach, a dishwasher with no isolation. This guide shows how to lay out a kitchen electrical plan that works for the household and for the installer.

Start with the fixed kitchen

Draw the walls, then the worktops, sink, hob and the appliance positions before you place a single socket. The worktop run decides where sockets are useful, and the sink and hob decide where they are not. Scanning the room with LiDAR gives you accurate wall lengths in seconds, and the worktops can be added as objects on top. For layout principles, see our guide to the kitchen work triangle.

USB C1 C2 C4 Kitchen Kitchen electrical plan Ring, cooker circuit and lighting CIRCUITS (CABLE ROUTES) C1 Lighting 1.5 mm² · 6 A RCBO C2 Kitchen ring 2.5 mm² · 32 A RCBO C4 Cooker 6 mm² · 32 A RCBO Connection (switch to light) SYMBOLS Surface ceiling light One-way switch Double socket Fused spur Cooker Control Unit Consumer Unit
A kitchen electrical plan: the kitchen ring (blue) feeds worktop sockets and fused spurs, the cooker circuit (purple) runs to its control unit, and one switch controls both ceiling lights.

Key takeaways

  • Draw the worktops, sink, hob and appliances before placing any socket.
  • Keep sockets away from the sink and never directly above the hob.
  • Give each integrated appliance a switched fused spur you can reach.
  • The cooker has its own circuit, with a control unit to one side of the hob.

Sockets above the worktop

  • Put double sockets along the worktop where small appliances actually live, typically one every metre or so of usable worktop.
  • Keep sockets and switches away from the sink and not directly above the hob. Many designers keep them at least 300 mm horizontally from the sink edge.
  • A kitchen usually gets its own ring final or radial because of the appliance load.

Fused spurs for fixed appliances

Integrated appliances such as the dishwasher, washing machine, fridge freezer and extractor hood are usually plugged into sockets hidden behind the units, with a switched fused spur above the worktop to isolate each one. Draw both: the fused spur on the wall you can reach, and the outlet it serves. That way the plan doubles as a guide to which switch isolates which appliance.

The cooker circuit

An electric oven and hob normally have a dedicated radial from the consumer unit to a cooker control unit or isolator placed to one side of the hob, within easy reach and never directly above it. A 32 A circuit in 6 mm² cable is common for typical domestic cooking appliances, but larger ranges can need more. Size it from the appliance rating, diversity, cable length and installation method.

Tip. Give the kitchen ring and the cooker circuit their own colours and label the routes with their length on plan. The report then lists each circuit's cable separately, which makes the quote easy to check.

Common mistakes

  • No way to isolate integrated appliances. A socket behind a dishwasher is useless without a switched spur you can reach.
  • The cooker switch above the hob. Reaching across hot pans to isolate a cooker is exactly what the layout should avoid.
  • Sockets where the worktop is not. Draw the worktops first, then place sockets where people will actually use them.
  • Forgetting the island. Islands need power planned before the floor goes down.

Lighting the work surfaces

Ceiling lights in the middle of a kitchen throw your shadow onto the worktop. Add downlights or under-cabinet lights over the work surfaces, link them to their switch with Connections, and the whole kitchen lighting scheme reads on one sheet. Read more trade guides on our electricians page.

Frequently asked questions

How many sockets should a kitchen have?

There is no legal number. Six to ten double sockets is a common recommendation, placed along the worktop where appliances are used, plus spurs for fixed appliances.

Does a kitchen need its own circuit?

Usually, yes. The appliance load is high, so a kitchen normally has its own ring or radial, with a separate circuit for the cooker.

Where should the cooker switch go?

To one side of the hob, within easy reach and never directly above it.

Free lesson. Want the full picture? Kitchens and bathrooms is part of our free electrical floor plans course, with interactive exercises.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read
Browse all guides