Mains Smoke Alarm Wiring Plan: Interlinked Alarms on a Floor Plan

Plan mains-powered interlinked smoke and heat alarms on a floor plan: BS 5839-6 grades and categories, where each alarm goes and how the interlink runs.

3 min read · 20 November 2026 · RoomPlot Team

Mains smoke and heat alarms are one of the most common jobs in domestic electrical work, and one of the most scrutinised. A plan that shows each alarm, its type and the interlink between them makes the design easy to agree with the client, the landlord or building control. This guide covers what to put where.

Grade and category first

In UK dwellings the reference is BS 5839-6. The grade describes how the system is powered and the category describes which rooms get detection:

  • Grade D1 - mains-powered alarms with a tamper-proof standby battery, widely recommended for rented homes. Grade D2 uses a user-replaceable battery.
  • Category LD2 - smoke alarms on the escape route (hall and landings), a smoke alarm in the principal habitable room and a heat alarm in the kitchen.
  • Category LD3 - escape route coverage only, the minimum in many cases.
Living / kitchen Bedroom Bathroom Hall Bedroom 2 Interlinked alarms Two-bedroom flat, LD2 style CIRCUITS (CABLE ROUTES) Alarm interlink Links every alarm, so one sounds them all C1 Lighting (supply) Alarms fed from a regularly used circuit SYMBOLS Smoke Alarm Heat Alarm Pendant fixture light Surface ceiling light Recessed ceiling light Consumer Unit
A minimal flat with an LD2 style layout: smoke alarms in the hall and living room, a heat alarm in the kitchen area and a smoke alarm in the bedroom, all interlinked (red) and supplied from the lighting circuit.

Key takeaways

  • BS 5839-6 sets the grade, which is how alarms are powered, and the category, which is where they go.
  • Smoke alarms cover escape routes and living rooms. A heat alarm goes in the kitchen.
  • Alarms are interlinked so that one sounding triggers them all.
  • Supply them from a regularly used lighting circuit or a dedicated circuit.

Where each alarm goes

  • Smoke alarms in the hall and on every landing, so the escape route is covered.
  • A heat alarm in the kitchen, where a smoke alarm would false-alarm.
  • Smoke alarms in the living room and, where the specification asks for it, bedrooms.
  • Ceiling mounted, clear of walls, light fittings and corners, following the manufacturer's spacing.

Mains alarms are usually supplied from a regularly used lighting circuit, so a tripped circuit is noticed quickly, or from their own dedicated circuit. The alarms are then interlinked so that one alarm sounding triggers them all, either with a three-core and earth interlink cable or with radio interlink modules. On the plan, draw the supply as part of the lighting circuit and the interlink as its own cable route in a distinct colour.

Check the standard. Requirements differ across the UK and by tenure. England's landlord rules require at least one smoke alarm on each storey with living accommodation and a carbon monoxide alarm in rooms with a fixed combustion appliance, other than gas cookers. Scotland requires interlinked alarms in every home. Always confirm the required grade and category before you quote.

Common mistakes

  • A smoke alarm in the kitchen. Cooking fumes cause false alarms; a heat alarm is the usual choice there.
  • Alarms not interlinked. An alarm in a closed bedroom that only sounds in the kitchen does little good.
  • Alarms on a little-used circuit. A tripped circuit nobody notices leaves the alarms on battery alone.
  • Too close to walls and lights. Follow the manufacturer's siting distances on the plan.

Commercial work is different

For offices, shops and HMOs on a panel system, detection is designed to BS 5839-1 with coverage radii and zones. RoomPlot's Fire Safety library draws detector coverage on the plan for that kind of work; see our guides to smoke detector coverage and the fire alarm zone plan. More guides for the trade are on our electricians page.

Frequently asked questions

Do smoke alarms need to be hard-wired?

For new homes and many rented homes, mains-powered alarms with a backup battery are the expected standard. The required grade depends on the property and the nation.

Can I put a smoke alarm in a kitchen?

A heat alarm is the usual choice in a kitchen, because cooking fumes set off smoke alarms.

How are alarms interlinked?

Either through an interlink conductor in a three-core and earth cable between alarms, or by radio modules.

Free lesson. Want the full picture? Circuits explained is part of our free electrical floor plans course, with interactive exercises.

Related guides

Electricians AFCI Requirements Explained: Which Rooms Need Arc-Fault Protection AFCI protection explained for US homes: what an arc fault is, the NEC 210.12 room list, what happens when you extend a circuit and how to plan it. 3 min read Electricians Consumer Unit Replacement in the UK: What Is Involved and What a Good Quote Includes Replacing a fuse box in the UK: what a modern consumer unit includes, the testing and certificates involved, Part P notification and how a circuit plan helps. 4 min read Electricians Cooker Circuit Guide: Cable Size, Diversity and the Cooker Switch UK cooker circuits explained: how diversity turns a 12 kW cooker into a 32 A circuit, typical cable sizes, where the cooker switch goes and how to draw it. 3 min read